RO Sizing Calculator – Liquid

RO Sizing Calculator – Liquid

Calculate orifice diameter for reverse osmosis systems based on flow rate, pressure drop, pipe dimensions, and fluid properties

Note: Yellow fields are inputs. All calculations update automatically.
📝

Input Parameters

kg/hr
bar
mm
mm
kg/m³
📊

Calculation Results

Diameter Ratio (d/D)
0.30
Orifice Diameter (Calculated)
7.2mm
Volumetric Flow Rate
1.0m³/h
Pressure Drop
0.62bar
Calculation Formula
d = √[(4 × Q) / (C × π × √(2 × ΔP / ρ))]

Where:

  • d = Orifice diameter (m)
  • Q = Volumetric flow rate (m³/s)
  • C = Discharge coefficient
  • ΔP = Pressure drop (Pa)
  • ρ = Density (kg/m³)

RO Sizing Calculator for Liquid Flow | Based on Crane Technical Paper A-20